TECHNICAL PUBLICATION #33A
MODERN COAXIAL LIGHTNING ARRESTORS: ALPHA DELTA VS. I.C.E.
This is a comparison report between coaxial lightning arrestor units manufactured by Alpha Delta Corp. and Industrial
Communication Engineers, Ltd. Both companies make a variety of such protective devices and are sold worldwide.
The I.C.E. design described in this report is protected by a patent issued by the U.S. Bureau of Patents and
Trademarks in Washington, D.C.,
Alpha Delta's primary configuration is a one part system consisting of a gas discharge breakdown unit connected in a
shielded enclosure between the coaxial center conductor and an insulated, external ground terminal fitting protruding
through the case. The gas discharge unit (GDU) has a rated breakdown voltage in the 400-1000 volt range to allow the
transmission of an-RF waveform through the unit without creating a sufficient voltage potential referenced to ground
to ignite the conductor referenced to ground the gas unit ignites, creating a temporary low resistance path to ground,
thus neutralizing the potential.
While this arrangement may be suitable protection in a few cases it suffers from numerous limitations that we believe
to be serious. Among them:
1) The case of the unit that is connected to the coaxial cable outer conductor passes throughout the unit and no
provision is made for grounding the case directly to earth ground. In lightning strike applications, both direct hits and
indirectly (inductively) coupled events, measurement studies have shown that as much as 80% of the incoming surge
flows down the exposed shield of the cable. The unfortunate result is that a large amount of the strike simply passes
across the arrestor chassis and reaches station equipment frames, dividing between many destructive paths seeking
ground.
2) The unit uses a pass-through center conductor. Although the gas discharge assembly will ignite when the
breakdown potential is reached many hundreds of volts are presented to the input of the radio equipment before the
arrestor action occurs. In modem solid state terms it means that the radio will nearly always be damaged or destroyed
before the arrestor activates to neutralize the income electromagnetic wavefront.
3) The use of a gas discharge unit as a sole-source mechanism for neutralizing lightning currents delivered by heavy
coaxial cable line conductors is controversial. Gas units have only a small dissipative power rating, seldom exceeding,
I watt. While the devices can handle large jolts of thousands of amperes of current, they can perform that service only
if the entire impact event lasts only a few microseconds. Lightning currents, especially slowed down by time
constants due to the inductance of transmission line conductors are much slower to rise, endure, and dissipate. The
result is frequent rupture and failure of the GDU, requiring down time and parts replacement. Additionally, it's
difficult to determine the condition of a GDU in service, notably after they have taken a few suspected "hits." They
don't always go short circuit, but they sometimes fracture and separate.
4) No constant drain method is employed to leak static development from cables. A coaxial line often acts like a large
capacitor, storing electrical charge which can only leak off the line through antenna joint connections or through the
insulated dielectric region between the conductors. When this occurs it nearly always causes receiver "hash" noise
during electrical activity.
The I.C.E. design, shown below on the right side, took these characteristics into account during development and
testing. Our arrangement uses a central high voltage rated blocking capacitor which allows the free flow of RF energy
through the arrestor device but blocks DC voltage and low frequency AC voltage. The heavy inductor on the antenna
side of the unit is the primary neutralizing agent. Voltage development is quickly shunted to ground through the DC
shorting nature of the inductor/RF choke. If large currents of a fast-rising nature are presented to the arrestor in such a
way that a back-EMF develops across the inductor then the companion paralleled gas discharge unit ignites, but its
only workload is to collapse the short-lived magnetic field of the inductor., The result is an arrestor that is constantly
active, requires no predetermined voltage to activate, and whose GDU workload is so low that is will probably last
forever. To date not a single replacement gas unit has been sold by us. The added resistance on the equipment side of
the arrestor was inserted to provide a similar drain function on the user side of the arrestor, shunting away tiny
currents that may appear from capacitor dielectric leakage during an impact event.